Chapter 3 · Site checks
24
Chapter 3 · ON CAFE worked example
Tool 2 · Site checks
ON CAFE's site-check record
This record follows receipt of existing documents and a visit with professionals. Compare the observations and unknowns in each row. In your record, also note when each document arrived and what supports each answer.
| Item | Observed or received | Still to verify | Who to ask / next request |
|---|---|---|---|
| Use records and lease | Records show food/beverage use. Draft lease: cafe, no alcohol. | Approvals for this plan; final lease wording | Designer: compare the plan. Lease reviewer: check final wording. |
| Zoning use | Cannot be verified by observing the site. | Whether cafe use and outdoor seating are allowed here | Ask the designer for a written planning-department response. |
| Electrical | Label photo shows 200A, single-phase. | Actual supply, existing loads such as HVAC, and capacity for new equipment | Designer: calculate loads for both water-heater options. |
| Gas | A meter is visible. | Service availability, piping and meter capacity, reconnection conditions | Send gas-water-heater information to the designer and gas utility. |
| Oven exhaust | No hood is visible. | Exhaust required for the selected oven and menu | Send oven specifications to the designer for agency confirmation. |
| Grease trap | Not located during the visit. | Whether a unit exists; applicable requirements, location and size | Designer: obtain landlord drawings and the sewer authority's reply. |
| Restroom | One restroom; the doorway looks narrow. | Actual dimensions, accessibility and occupant-load requirements | Have the designer measure it, then identify changes and costs. |
| Water heater and sinks | Present, but not tested because power was off. | Ownership, transfer terms, operating condition and suitability | Landlord: written list and power. Service provider: condition check. |
| Outdoor use and signs | Space in front of the unit and the previous sign location are visible. | Use rights, landlord consent and agency requirements | Broker: written consent terms. Sign contractor: permit process. |
2
Tool 2 · Site checks
Record observations and unknowns separately. If only part of an item is verified, keep the remaining question open.
"Cannot be verified by observing the site" is not the same as "Not applicable." Use "Not applicable" only when an item truly does not apply, such as alcohol sales under the current no-alcohol plan.
PREVIEW · C0 · 9 / 43